Router()->add('products', '/proizvodi/:category/:serie/:line', array('controller'=>'products','module'=>'products','action'=>'view','id'=>true,'page_slug'=>'/proizvodi')); TESY | Heat pump for DWH AquaThermica 200l with coil

A sustainable product worikin  on renewable energy sources, which contributes to a clean environment by significantly reducing CO2 emissions*.

Highest energy efficiency class in this category A+ according to ErP regulations**.

Wide operating range of the incoming air temperature from -10°C to +43°C.

Water heating up to 65°C only with the heat pump unit.

Built-in electric heater for faster heating and reaching a temperature of 75°C.

High efficiency thanks to electronic expansion valve for a precisely balanced refrigerant cycle.

Up to 75% reduced energy consumption ***

Possibility to connect to other renewable energy sources such as photovoltaic and solar systems or boilers.

Programmable module and user-friendly control panel.

Automatic anti-Legionella cycle.

Self-diagnostic system.

*According to the European Heat Pump Association's 2018 European Market and Statistics Report on Heat Pumps.

** AquaThermica falls into energy class A+

*** Compared to a TESY branded product from the MaxEau family, model GCV 200 56 20 D06 SRC Energy Class C

SAP 305277
Capacity 194 L
Insulation 50 mm
Energy class A+
Maximum
operational temperature
75 °C
Maximum working pressure 8 bar
Diameter 630 mm
Heating time 8:59 h:min
Declared load profile L
Electric heating element power 1.5 kW
HP maximum absorption 0.663 + 1.5 (e-heater) = 2.163 kW
Min. ÷ max temperature heat pump air intake (90% R.H.) -10 ÷ 43 °C
Frequency 50 Hz
Annual electricity consumption in kWh under average climate conditions 811.7 kWh
Power supply 230 V
Compressor Rotary
Min. ÷ max temperature installation site -10 ÷ 43 °C
Compressor protection Thermal circuit breaker with automatic reset
Maximum current in HP 3.1 + 6.5 (e-heater) = 9.6 A
Thermodynamic circuit protection type Safety pressure switch with automatic reset
Required overload protections 16A T fuse/ 16 A automatic switch characteristic C (to be expected during installation on power supply systems)
Fan Centrifugal
HP Maximum settable temperature 65 °C
Internal protection Single safety thermostat with manual reset on a resistive element
Nominal air capacity 314 m³/h
Max. pressure head available 50 Pa
Motor protection Internal thermal circuit breaker with automatic reset
Condenser Wrapped externally not in contact with water
Coil for connection to solar thermal power system 1.0 m²
Coil for connection to an auxiliary heating source N/A m²
Transport weight 112 kg
Sound power Lw (A) 53 dB(A)
Automatic anti-Legionnella disinfection cycle YES
Minimum height of the premise 1785 mm
Cathodic protection Mg anode Ø 32 x 400 mm
Defrosting 4-way valve
CoP (DHW) 3.1
Degree of Protection IPX4
Refrigerant R134a
Refrigerant charge 880 g
CO2 equivalent (CO2e) 1287 t
Volume of mixed water at 40º / V40 (EN 16147:2017 - A7/W55) 262 L
Average heat pump consumption [Condition EN16147:2017 A7/W55] 0.43 kW