* Required fields
A sustainable product worikin on renewable energy sources, which contributes to a clean environment by significantly reducing CO2 emissions*.
Highest energy efficiency class in this category A+ according to ErP regulations**.
Wide operating range of the incoming air temperature from -10°C to +43°C.
Water heating up to 65°C only with the heat pump unit.
Built-in electric heater for faster heating and reaching a temperature of 75°C.
High efficiency thanks to electronic expansion valve for a precisely balanced refrigerant cycle.
Up to 75% reduced energy consumption ***
Possibility to connect to other renewable energy sources such as photovoltaic and solar systems or boilers.
Programmable module and user-friendly control panel.
Automatic anti-Legionella cycle.
Self-diagnostic system.
*According to the European Heat Pump Association's 2018 European Market and Statistics Report on Heat Pumps.
** AquaThermica falls into energy class A+
*** Compared to a TESY branded product from the MaxEau family, model GCV 200 56 20 D06 SRC Energy Class C
SAP | 305277 |
Capacity | 194 L |
Insulation | 50 mm |
Energy class | A+ |
Maximum operational temperature | 75 °C |
Maximum working pressure | 8 bar |
Diameter | 630 mm |
Heating time | 8:59 h:min |
Declared load profile | L |
Electric heating element power | 1.5 kW |
HP maximum absorption | 0.663 + 1.5 (e-heater) = 2.163 kW |
Min. ÷ max temperature heat pump air intake (90% R.H.) | -10 ÷ 43 °C |
Frequency | 50 Hz |
Annual electricity consumption in kWh under average climate conditions | 811.7 kWh |
Power supply | 230 V |
Compressor | Rotary |
Min. ÷ max temperature installation site | -10 ÷ 43 °C |
Compressor protection | Thermal circuit breaker with automatic reset |
Maximum current in HP | 3.1 + 6.5 (e-heater) = 9.6 A |
Thermodynamic circuit protection type | Safety pressure switch with automatic reset |
Required overload protections | 16A T fuse/ 16 A automatic switch characteristic C (to be expected during installation on power supply systems) |
Fan | Centrifugal |
HP Maximum settable temperature | 65 °C |
Internal protection | Single safety thermostat with manual reset on a resistive element |
Nominal air capacity | 314 m³/h |
Max. pressure head available | 50 Pa |
Motor protection | Internal thermal circuit breaker with automatic reset |
Condenser | Wrapped externally not in contact with water |
Coil for connection to solar thermal power system | 1.0 m² |
Coil for connection to an auxiliary heating source | N/A m² |
Transport weight | 112 kg |
Sound power Lw (A) | 53 dB(A) |
Automatic anti-Legionnella disinfection cycle | YES |
Minimum height of the premise | 1785 mm |
Cathodic protection | Mg anode Ø 32 x 400 mm |
Defrosting | 4-way valve |
CoP (DHW) | 3.1 |
Degree of Protection | IPX4 |
Refrigerant | R134a |
Refrigerant charge | 880 g |
CO2 equivalent (CO2e) | 1287 t |
Volume of mixed water at 40º / V40 (EN 16147:2017 - A7/W55) | 262 L |
Average heat pump consumption [Condition EN16147:2017 A7/W55] | 0.43 kW |