Maximum working pressure 8 bar
Energy class A+
Diameter 630 mm
Maximum
operational temperature
75 °C
Capacity 202 L
Thermo pocket x1 pieces
Heating time 8:59 h:min
Declared load profile L
Insulation (rigid PU) 50 mm
Electric heating element power 1.5 kW
HP maximum absorption 0.663 + 1.5 (e-heater) = 2.163 kW
Min. ÷ max temperature heat pump air intake (90% R.H.) -10 ÷ 43 °C
Frequency 50 Hz
Annual electricity consumption in kWh under average climate conditions 811.7 kWh
Power supply 230 V
Compressor Rotary
Min. ÷ max temperature installation site -10 ÷ 43 °C
Compressor protection Thermal circuit breaker with automatic reset
Maximum current in HP 3.1 + 6.5 (e-heater) = 9.6 A
Thermodynamic circuit protection type Safety pressure switch with automatic reset
Required overload protections 16A T fuse/ 16 A automatic switch characteristic C (to be expected during installation on power supply systems)
Fan Centrifugal
HP Maximum settable temperature 65 °C
Internal protection Single safety thermostat with manual reset on a resistive element
Nominal air capacity 314 m³/h
Max. pressure head available 50 Pa
Motor protection Internal thermal circuit breaker with automatic reset
Condenser Wrapped externally not in contact with water
Coil for connection to solar thermal power system 1.0 m²
Coil for connection to an auxiliary heating source N/A m²
Transport weight 96 kg
Sound power Lw (A) 53 dB(A)
Automatic anti-Legionnella disinfection cycle YES
Height 1720 mm
Minimum height of the premise 1785 mm
Cathodic protection Mg anode Ø 32 x 400 mm
Defrosting 4-way valve
CoP (DHW) 2.9
Heat Pump Thermal Power yield (P rated) 1.1 kW
Degree of Protection IPX4
Refrigerant R134a
Refrigerant charge 880 g
Global Worming potential 1430
CO2 equivalent 1287 t
Max. quantity of hot water at 40; V40; [EN16147:2017] 272 L
Average heat pump consumption [Condition EN16147:2017 A7/W55] 0.43 kW