• ERP A+
  • Optional connections to solar thermal and photovoltaic systems
  • Minimum and maximum temperature of the incoming air:( at 90% R.H): +4 up to +43 ⁰ C
  • Operation modes - Automatic / Economy / Rapid heating   
  • Automatic defrost system.   
  • Anti-Legionellae disinfection cycle
  • Low noise levels   
  • Highly efficient rotary compressor   
  • Eco friendly refrigerant   
  • COP 2.8 – 3.1 according to EN16147  Indoor 20 ⁰c  
  • High quality of the materials (e.g. the external cover in PVC can easily replaced in case of damage; high quality tank with 3mm thickness, butt welding, enameling according UNI standards, two sacrificial anodes for the 260 liters and 200 liters versions with additional coil)
  • No need for special accessories to assemble the pipes for the air intake and outlet
  • Digital input to store surplus energy produced by the photovoltaic system
  • Digital input with intelligent “smart grid” mode to optimize the operation of the solar heating system (it avoids energy waste when the solar heating system is activated);
  • Possibility to work with timeslots in order to concentrate the energy consumption when the electricity costs less
Maximum working pressure 8 bar
Energy class А+
Diameter 600 mm
HP thermal power yield 1.6 kW
Capacity 200 L
Heating time 07:16 h:min
Declared load profile L
Electric heating element power 1.5 kW
HP maximum absorption 0.5 kW
Min. ÷ max temperature heat pump air intake (90% R.H.) 4÷43 °C
Frequency 50 Hz
Annual electricity consumption in kWh under average climate conditions 929 kWh
Power supply 1/N/230 V
Compressor Rotary
Min. ÷ max temperature installation site 4÷43 °C
Compressor protection Thermal circuit breaker with automatic reset
Average consumption 0.37 kW
Maximum current in HP 2.3 A
Thermodynamic circuit protection type Safety pressure switch with automatic reset
Fan Centrifugal
HP Maximum settable temperature 56 °C
Internal protection Single safety thermostat with manual reset on a resistive element
Nominal air capacity 350 m³/h
Max. pressure head available 100 Pa
Motor protection Internal thermal circuit breaker with automatic reset
Condenser Wrapped externally not in contact with water
Coil for connection to solar thermal power system 0.96 m²
Coil for connection to an auxiliary heating source N/A m²
Transport weight 94 kg
Sound power Lw (A) 59 dB(A)
Automatic anti-Legionnella disinfection cycle YES
Height 1714 mm
Minimum height of the premise 1751 mm