* Required fields
Floor-standing "air-water" heat pump for domestic hot water production.
The AquaThermica Eco range includes models with a volume of 200 and 260 liters with and without a heat exchanger
Greater energy efficiency and performance are guaranteed by environmentally friendly refrigerant R513a.
Electric heater for faster heating and reaching a high temperature of 75°C.
Automatic "Antilegionella" function and self-diagnosis system
Floor standing models
Energy class A+
Reduced CO2 emissions
Electronically regulated expansion valve with stepper motor
Water tank capacity from 200 to 260 L
Temperature range of the incoming air from -10°С to +43°С
Up to 75% reduced electricity consumption
Connection to solar and photovoltaic panels
Easy-to-use electronic panel
Up to 65°C DHW temperature with operation of only the heat pump unit
Connection to solar and photovoltaic panels
EEV Electronically regulated expansion valve with step motor
Easy-to-use electronic panel
| TIN Code | 305765 |
| Range | 194 |
| Height | 1720 m |
| Energy class | A+ |
| Maximum operational temperature | 75 °C |
| Maximum working pressure | 8 bar |
| Diameter | 630 mm |
| Heating time | 6:33 h:min |
| Declared load profile | L |
| Electric heating element power | 1.5 kW |
| Min. ÷ max temperature heat pump air intake (90% R.H.) | -10 ÷ 43 °C |
| Frequency | 50 Hz |
| Annual electricity consumption in kWh under average climate conditions | 702 kWh |
| Power supply | 1/N/220-240 V |
| Compressor | Rotary |
| Min. ÷ max temperature installation site | -4 ÷ 40 °C |
| Compressor protection | Thermal circuit breaker with automatic reset |
| Maximum current in HP | 3.1 + 6.5 (e-heater) = 9.6 A |
| Required overload protections | 16A T fuse/ 16 A automatic switch characteristic C (to be expected during installation on power supply systems) |
| Fan | Centrifugal |
| HP Maximum settable temperature | 65 °C |
| Internal protection | Single safety thermostat with manual reset on a resistive element |
| Nominal air capacity | 360 m³/h |
| Motor protection | Internal thermal circuit breaker with automatic reset |
| Condenser | Wrapped externally not in contact with water |
| Transport weight | 121 kg |
| Automatic anti-Legionnella disinfection cycle | YES |
| Minimum height of the premise | 1785 mm |
| Defrosting | Active with 4-way valve |
| CoP (DHW) | 3.5 |
| Degree of Protection | IPX4 |
| Refrigerant | R513a |
| Refrigerant charge | 1100 g |
| CO2 equivalent (CO2e) | 0.693 |
| Average heat pump consumption [Condition EN16147:2017 A7/W55] | 0.403 kW |