TESY AquaThermica Pro is a floor standing air-to-water heat pump for domestic hot water engineered for high energy efficiency, smart performance, and eco-conscious operation. Designed for domestic hot water production, it is available in 200L and 260L capacities

Using the natural R290 (propane) refrigerant, AquaThermica Pro achieves ultra-low Global Warming Potential (GWP) and zero Ozone Depletion Potential (ODP). It can heat water up to 65°C using only the heat pump, offering energy savings versus conventional electric water heaters. Its high Coefficient of Performance (COP)—up to 3.8—makes it one of the most efficient systems in its class.

  • Floor-standing "air-water" heat pump for domestic hot water production.
  • The AquaThermica Pro range includes models with a volume of 200 and 260 liters  without a heat exchanger
  • Greater energy efficiency and performance = > ecofriendly refrigerant R290 /propane/
  • Electric heater for faster heating and reaching a high temperature of 75°C
  • Automatic "Antilegionella" function and self-diagnosis system
  • Energy class A+
  • Reduced CO2 emissions
  • Temperature range of the incoming air from -7°С to +43°С
  •  reduced electricity consumption
  • Lateral 45° air ducts for installation in rooms as low as 2 meters
  • Quiet operation: just 34 dB(A) at 1 meter
  • DRY CHECK Check the magnesuim anode without draining the water.
  • Electronic Expansion Valve (EEV) for precision refrigerant control
  • Microchannel condenser and dual temperature sensors for performance and efficiency
  • Connection to solar and photovoltaic panels
  • Easy-to-use electronic panel
TIN Code 306179
Capacity 260 L
Range 260
Height 1911 m
Energy class A+
Maximum
operational temperature
75 °C
Maximum working pressure 8 bar
Diameter 630 mm
Declared load profile XL
Electric heating element power 1.5 kW
Min. ÷ max temperature heat pump air intake (90% R.H.) -7 ÷ 43 °C
Frequency 50 Hz
Annual electricity consumption in kWh under average climate conditions 1152 kWh
Power supply 1/N/220-240 V
Compressor Rotary
Min. ÷ max temperature installation site -4 ÷ 40 °C
Compressor protection Thermal circuit breaker with automatic reset
Maximum current in HP 2.5 + 6.5 (e-heater) = 9 A
Required overload protections 16A T fuse/ 16 A automatic switch characteristic C (to be expected during installation on power supply systems)
Fan Centrifugal
HP Maximum settable temperature 65 °C
Internal protection Single safety thermostat with manual reset on a resistive element
Nominal air capacity 360 m³/h
Motor protection Internal thermal circuit breaker with automatic reset
Condenser Wrapped externally not in contact with water
Transport weight 112,8 kg
Automatic anti-Legionnella disinfection cycle YES
Minimum height of the premise 2000 mm
Defrosting Active 4-way valve
CoP (DHW) 3.8
Degree of Protection IPX4
Refrigerant R290
Refrigerant charge 150
Average heat pump consumption [Condition EN16147:2017 A7/W55] 0.400 kW